:: Volume 18, Issue 4 (12-2016) ::
J Gorgan Univ Med Sci 2016, 18(4): 81-87 Back to browse issues page
Comparison of the accuracy of various methods of measuring body temperature in three months to five years old children
S Kkazemimajd * 1, Z Amiri2 , F Jahanpoor3 , F Rostami4
1- M.Sc in Biostatistics, Department of Biostatistics, Paramedical Sciences Faculty, Shahid Beheshti University of Medicine Sciences, Tehran, Iran , csomaieh@yahoo.com
2- Associate Professor, Institut Pasteur Research Centre, School Nutrition, Shahid Beheshti University of Medical Sciences, Tehran, Iran
3- Associate Professor, Department of Nursing, Nursing Faculty, Bushehr University of Medical Sciences, Bushehr, Iran
4- Nurse, Department of Nursing, Paramedical Faculty, Shahid Beheshti University of Medical Sciences, Tehran, Iran
Abstract:   (9477 Views)

Background and Objective: Several methods are available for measuring fever in children. This study was done to compare the accuracy of three method of measuring body temperature using left and right tympanic, axillary and rectal methods in three months to five years old children.

Methods: This descriptive-analytic study was done on 126 children (63 without fever and 63 children with fever) with 3 months to 5 years age in Mofid hospital, Tehran, Iran. Rectal temperature lower than 38°C was considered as Gold standard to determine fever. Body temperature was also recorded for subjects through right and left tympanic and axilary methods.

Results: Body temperature was recorded in axillary method 37.1°C (sensitivity: 92.1%, specificity: 90.5%), right tympanic 36.9°C (sensitivity: 74.6%, specificity: 84.13%) and left tympanic 37.3°C (sensitivity: 93.65%, specificity: 84.13%). The mean temperature in the axillary method 0.77°C, right tympanic 1.02°C and left tympanic 0.48°C was lower than the mean rectal method (P<0.05). The correlation between right, left tympanic and axillary with rectal method was 0.84, 0.894 and 0.925, respectively (P<0.05). The area under the receiver operating characteristic (ROC) curve for left and right tympanic and axillary were 0.95, 0.87, 0.965, respectively.

Conclusion: The difference between rectal and left tympanic method was at the lowest level due to the ease of measuring temperature through tympanic membrane in three months to five years old children.

Keywords: Fever, Rectal method, Axillary method, Tympanic method, Child
Full-Text [PDF 217 kb] [English Abstract]   (21412 Downloads) |   |   Abstract (HTML)  (1462 Views)  
Type of Study: Original Articles | Subject: Pediatric
References
1. Beckstrand RL, Wilshaw R, Moran S, Schaalje GB. Supralingual temperatures compared to tympanic and rectal temperatures. Pediatr Nurs. 1996 Sep-Oct; 22(5): 436-8.
2. Haddock BJ, Merrow DL, Swanson MS. The falling grace of axillary temperatures. Pediatr Nurs. 1996 Mar-Apr; 22(2): 121-5.
3. Bailey J, Rose P. Axillary and tympanic membrane temperature recording in the preterm neonate: a comparative study. J Adv Nurs. 2001 May; 34(4): 465-74.
4. Stewart JV, Webster D. Re-evaluation of the tympanic thermometer in the emergency department. Ann Emerg Med. 1992 Feb; 21(2): 158-61.
5. Gasim GI, Musa IR, Abdien MT, Adam I. Accuracy of tympanic temperature measurement using an infrared tympanic membrane thermometer. BMC Res Notes. 2013; 6: 194. doi:10.1186/1756-0500-6-194
6. Arslan GG, Eser I, Khorshid L. Analysis of the effect of lying on the ear on body temperature measurement using a tympanic thermometer. J Pak Med Assoc. 2011 Nov; 61(11): 1065-8.
7. Zare N, Namdari M, Jahanpour F. Comparison of axillary, tympanic and rectal body term-peratures using a covariate-adjusted receiver operating characteristic approach. Iran Red Crescent Med J. 2010 May; 12(3): 293-97.
8. Haddadin RB, Shamoon HI. Study between axillary and rectal temperature measurements in children. East Mediterr Health J. 2007; 13(5): 1060-66.
9. Lachenbruch PA, Lynch CJ. Assessing screening tests: extensions of McNemar's test. Stat Med. 1998 Oct;17(19):2207-17.
10. Khosravi A, Sohrabi M B, Haratipoor H, Zolfaghari P. [Accuracy and precision of body temperature measurement with infrared tympanic and axiliary thermometers compared with standard oral mercury thermometer]. FEYZ. 2006; 9(4): 43-49. [Article in Persian]
11. Basak T, Aciksoz S, Tosun B. Comparison of measurement results of three different types of thermometers in evaluation of body temperatures of healthy young adults. 23rd International Nursing Reaserch Congress. 3 Agust 2012.
12. Rabbani MZ, Amir M, Malik M, Mufti M, Bin Pervez M, Iftekhar S. Tympanic temperature comparison with oral mercury thermometer readings in an OPD setting. J Coll Physicians Surg Pak. 2010 Jan; 20(1): 33-6. doi:01.2010/JCPSP.3336
13. Aciksoz S, Tosun B, Akyuz A, Acikel C. Comparison of three different thermometers in evaluating the body temperature of healthy young adult individuals. Int J Nurs Pract. 2013 Oct; 19(5): 471-78. doi:10.1111/ijn.12097
14. Sedaghat M, Kazemi R, Golmohammadi E. [Axillary temperature sensitivity and specificity in the diagnosis of fever]. Payesh. 2003; 2(4): 277-81. [Article in Persian]
15. Brennan DF, Falk JL, Roth rock SG. Reliabrhty of infrared tympanic thermometer in the detection of rectal fever in children. Ann Emerg Med. 1995; 25: 21-30.
16. Lanham DM, Walker B, Klocke E, Jennings M. Accuracy of tympanic temperature readings in children under 6 years of age. Pediatr Nurs. 1999 Jan-Feb; 25(1): 39-42.
17. Banitalebi H, Bangstad HJ. [Measurement of fever in children--is infrared tympanic thermometry reliable?]. Tidsskr Nor Laegeforen. 2002 Nov; 122(28): 2700-1. [Article in Norwegian]
18. Ferrara-Love R. A comparison of tympanic and pulmonary artery measures of core temperatures. J Post Anesth Nurs. 1991 Jun; 6(3): 161-4.
19. Erickson RS, Woo TM. Accuracy of infrared ear thermometry and traditional temperature methods in young children. Heart Lung. 1994 May-Jun; 23(3): 181-95.
20. Jahanpour F, Azodi P, Zare N. A comparative study on temperature accuracy between tympanic, rectal, and axillary sites. Iran J Med Sci. 2008; 33(1): 49-53.
Send email to the article author


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Kkazemimajd S, Amiri Z, Jahanpoor F, Rostami F. Comparison of the accuracy of various methods of measuring body temperature in three months to five years old children. J Gorgan Univ Med Sci 2016; 18 (4) :81-87
URL: http://goums.ac.ir/journal/article-1-2960-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 18, Issue 4 (12-2016) Back to browse issues page
مجله دانشگاه علوم پزشکی گرگان Journal of Gorgan University of Medical Sciences
Persian site map - English site map - Created in 0.05 seconds with 36 queries by YEKTAWEB 4679
Creative Commons License
This work is licensed under a Creative Commons — Attribution-NonCommercial 4.0 International (CC BY-NC 4.0)