[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Editorial Board::
Executive Members::
Instruction to Authors::
Peer Review::
Articles Archive::
Indexing Databases::
Contact Us::
Site Facilities::
::
Search in website

Advanced Search
Receive site information
Enter your Email in the following box to receive the site news and information.
:: Volume 3, Issue 2 (Autumn & Winter 2001) ::
J Gorgan Univ Med Sci 2001, 3(2): 12-18 Back to browse issues page
Establishment of IFA technique for detecting ANCA
M.Saeedi (M.Sc) * 1, H . Baradaran (Ph .D) , M.A Hatef (M.D)
Abstract:   (23844 Views)
ANCA are classes of antibodies or in reality autoantibodies usually produce in conditions that degradation of neutrophiles occurs. This is led to vascular damage. They are more common in rheumatic diseases such as Rheumatoid Arthritis (RA), systemic Lupus Erythematus (SLE) and vasculitic diseases especially Wegners’ granulomatosis (With specificity and sensitivity as high as 95%). We decided to design IFA-ANCA because this assay has high sensitivity and in with comparison other techniques such as ELISA & RIA is more economic and simple. On the other hand, screening test for determining ANCA is immunofluorescent assay. ANCA test establishment contains: Isolation of neutrophiles, fixation with Ethanol and Formalin, improvement of method and quality control by using of indirect immunofluorescence assay (IFA), 2 staining pattern are observed. Cytoplasmic (C-ANCA) or classic and prinuclear (P-ANCA) pattern. Established ANCA test by inter assay method had 95% reproducibility and 91% precision.
Keywords: ANCA, IFA
Full-Text [PDF 1112 kb]   (15886 Downloads)    
Type of Study: Original Articles | Subject: General
* Corresponding Author Address: Department of immunology , Gorgan University of Medical Sciences


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

M.Saeedi (M.Sc), H . Baradaran (Ph .D), M.A Hatef (M.D). Establishment of IFA technique for detecting ANCA . J Gorgan Univ Med Sci 2001; 3 (2) :12-18
URL: http://goums.ac.ir/journal/article-1-128-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 3, Issue 2 (Autumn & Winter 2001) Back to browse issues page
مجله دانشگاه علوم پزشکی گرگان Journal of Gorgan University of Medical Sciences
Persian site map - English site map - Created in 0.04 seconds with 36 queries by YEKTAWEB 4660
Creative Commons License
This work is licensed under a Creative Commons — Attribution-NonCommercial 4.0 International (CC BY-NC 4.0)