Search published articles


Showing 4 results for Bacterial Contamination

A R Abdolahi,
Volume 3, Issue 2 (10-2009)
Abstract

Abstract Background and objectives: A Nosocomial infection is one of the Leading problems causing high mortality among hospitalized patients. This study aimed at confirming the concurrence of Nosocomial infections with microorganisms spreading in the air of hospital wards. Material and Methods: This study was conducted in 2009 at ValieAsr Hospital in Tehran, Iran. The Samples were taken from the air of different sections of the hospital both actively (with Quick-Tak, 30) and passively. After that, the samples were investigated for bacerial and fungal contamination and the results were compared with the results of Laboratory Studies of patients in different wards. Results: The Bone Marrow Transplant (BMT) ward shows the least fungal and microbial contamination whiles the Intensive Care Unit (ICU) the highest. The fungi are essentially Cladosporium and penicillium while the most well-Known organisms are Micrococcus and Staphylococcus epidermidis. Stenotrophomonas is seen in both blood and air culture in thorax surgery ward. Also, the concurrence of Staphylococcus epidermidis in the samples of the air and patients is considerable. Conclusion: There isn’t concurrence between the Nosocomial caused organism, apart from Stenotrophomonas and Staphylococcus epidermidis, and microorganisms isolated from patients. Because the bacterial and fungal organisms are in the air of Hospital, it is a necessity to install proper ventilation system. Keywords: Air Bacterial Contamination, Hospital, Nosocomial Infection
P Torabi, M Azimirad, Z Hasani, M Janmaleki, H Peirovi, M Alebouyeh, Mr Zali,
Volume 8, Issue 1 (4-2014)
Abstract

Abstract Background and Objective: This study was aimed to determine the extent of bacterial contamination and drug resistance patterns of isolates colonized in colonoscope and endoscope and in relevant personnel. Material and Methods: A total of 107 samples were obtained from staff of endoscopy and colonoscopy units (SEU and SCU) and gastroenterological imaging equipment. For isolation and identification of the bacteria, swab culture method and biochemical identification test were used, respectively. Antimicrobial resistance profiles, multi-drug resistance (MDR) patterns and phenetic relatedness of these isolates were also analyzed according to standard methods. Results: Most frequent pathogenic bacteria among the SEU and gastroenterological imaging related equipments were included S. aureus (20.8 % and 0 %) Enterococcus spp. (0 % and 5.4%) Pseudomonas spp. (0% and 13.5 %), and Clostridium difficile (0% and 12.5%). Analysis of resistance phenotypes showed a high frequency of MDR phenotypes among the SEU (82.1%), and also in endoscopes, colonoscopes, and other equipments (20%, 50% and 100%, respectively). Phylotyping of S. epidermidis isolates showed the role of staff in transmission of resistance strains to medical equipments and also circulation of strains with identical resistance phenotype among the studied samples. Conclusion: High frequency of pathogenic bacteria in colonoscopes, endoscopes and in the staff of endoscopy & colonoscopy units, and also contamination of these instruments with MDR pathogens emphasize the need for proper disinfection of endoscopes and colonoscopes and also instruction of staff in these units. Key words: Bacterial Contamination Endoscope Colonoscope Antimicrobial Resistance Gastrointestinal Disease.
L Dolatshah, R Ghanbarpour, F Momeni, H Alizade,
Volume 8, Issue 1 (4-2014)
Abstract

Abstract Background and Objective: This study was aimed to determine the extent of bacterial contamination and drug resistance patterns of isolates colonized in colonoscope and endoscope and in relevant personnel. Material and Methods: A total of 107 samples were obtained from staff of endoscopy and colonoscopy units (SEU and SCU) and gastroenterological imaging equipment. For isolation and identification of the bacteria, swab culture method and biochemical identification test were used, respectively. Antimicrobial resistance profiles, multi-drug resistance (MDR) patterns and phenetic relatedness of these isolates were also analyzed according to standard methods. Results: Most frequent pathogenic bacteria among the SEU and gastroenterological imaging related equipments were included S. aureus (20.8 % and 0 %) Enterococcus spp. (0 % and 5.4%) Pseudomonas spp. (0% and 13.5 %), and Clostridium difficile (0% and 12.5%). Analysis of resistance phenotypes showed a high frequency of MDR phenotypes among the SEU (82.1%), and also in endoscopes, colonoscopes, and other equipments (20%, 50% and 100%, respectively). Phylotyping of S. epidermidis isolates showed the role of staff in transmission of resistance strains to medical equipments and also circulation of strains with identical resistance phenotype among the studied samples. Conclusion: High frequency of pathogenic bacteria in colonoscopes, endoscopes and in the staff of endoscopy & colonoscopy units, and also contamination of these instruments with MDR pathogens emphasize the need for proper disinfection of endoscopes and colonoscopes and also instruction of staff in these units. Key words: Bacterial Contamination Endoscope Colonoscope Antimicrobial Resistance Gastrointestinal Disease.
Moshtaghi, H, Parsa, M,
Volume 9, Issue 1 (4-2015)
Abstract

Abstract Background and Objective: Automated Teller Machine (ATMs) is likely to be contaminated with various microorganisms specially pathogen germs. This may be due to their exposure to dust and their vast dermal contact with multiple users. This study investigated the bacterial contamination on the keyboard of ATMs and drug resistance of the bacteria isolated from them. Material and Methods: the keyboards of 50 ATMs in Shahrekord city, Iran, were examined from October 2012 to February 2013. The sterile swab sticks moistened with Triptose soy broth were used for sampling. The bacteriological tests used were culture, biochemical test and agar disk diffusion method for antibiogram. Results: All the samples were found to be contaminated with Coagulase negative staphylococci (57.54%), Bacillus species (21.92%), Staphylococcus aureus (19.18%) and coliform bacteria (1.36%). The resistance of Staphylococcus aureus was 92.8% to penicillin, 85.7% to amoxicilin، 71.4% to ampicillin, 57.1% to nytrofuran, 50% to tetracycline, 42.8% to erythromycin, 42.8% to gentamycin, 14.2 % to ciprofloxacin, 7.1% to trimethoprim and sulfamtuksazul. All species were susceptible to, ofloxacine, chloramphenicol, clindamycin, tobramycin, vancomycin and cefotaxime. Conclusion: given the presence of pathogens on ATMs and their role in transferring the contamination, we recommend considering personal hygiene and periodically disinfecting the keyboards to reduce contamination. Keywords: ATMs, Bacterial Contamination, Antibiogram

Page 1 from 1     

© 2007 All Rights Reserved | Medical Laboratory Journal

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.