[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Editorial Board::
Executive Members::
Instruction to Authors::
Peer Review::
Articles Archive::
Indexing Databases::
Contact Us::
Site Facilities::
::
Search in website

Advanced Search
Receive site information
Enter your Email in the following box to receive the site news and information.
:: Volume 17, Issue 3 (10-2015) ::
J Gorgan Univ Med Sci 2015, 17(3): 108-113 Back to browse issues page
Comparison of fluorescent spot test, decolorization test and quantitative enzyme assay in detection of G6PD enzyme deficiency
Kosaryan M1 , Mahdavi MR * 2, Jalali H3 , Roshan P4
1- Professor, Department of Pediatrics, Thalassemia Research Center, Hemoglobinopathy Institute, Mazandaran University of Medical Sciences, Sari, Iran
2- Assistant Professor, Department of Laboratory Medicine, Mazandaran University of Medical Sciences, Sari, Iran , info@fajrlaboratory.com
3- Ph.D Candidate by Research in Thalassemia, Thalassemia Research Center, Hemoglobinopathy Institute, Mazandaran University of Medical Sciences, Sari, Iran
4- M.Sc in Immunology, Sina Mehr Research Center, Sari, Iran
Abstract:   (9280 Views)
Background and Objective: The national screening program for G6PD enzyme deficiency is not able to detect all affected neonates. This study was done to compare the fluorescent spot test (FST), decolorization test, and quantitative enzyme assay (QEA) for detecting G6PD enzyme deficiency in neonates. Methods: In this descriptive study, cord blood samples of 365 neonates were collected. Decolorization test, QEA and DNA test was done for each sample. All of the neonates were tested by FST as a part of national screening program on heel-prick blood sample collected on day 3–5 after birth. QEA was considered as the gold standard. According to QEA test results, neonates with <20% and 20–60% of mean normal enzyme activity were considered as total deficient and partial deficient, respectively. Results: Fluorescent spot test detected 13 male neonates with G6PD enzyme deficiency while decolorization test identified 18 male and 1 female neonates. Using QEA, 19 of male and 28 of female neonates with G6PD enzyme deficiency (26 cases with partial and 2 cases with total deficiency) were diagnosed. DNA analysis detected 34 female case as heterozygote and 14 male neonates as hemizygote for the disease. Conclusion: Fluorescent spot test do not have required sensitivity for screening of neonates with G6PD enzyme deficiency. QEA test is recommended to replace the fluorescent spot test in national screening program.
Keywords: G6PD enzyme deficiency, Fluorescent spot test, Decolorization test, Quantitative enzyme assay, DNA test
Full-Text [PDF 200 kb] [English Abstract]   (15267 Downloads)    
Type of Study: Original Articles | Subject: Hematology
Send email to the article author


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Kosaryan M, Mahdavi MR, Jalali H, Roshan P. Comparison of fluorescent spot test, decolorization test and quantitative enzyme assay in detection of G6PD enzyme deficiency. J Gorgan Univ Med Sci 2015; 17 (3) :108-113
URL: http://goums.ac.ir/journal/article-1-2510-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 17, Issue 3 (10-2015) Back to browse issues page
مجله دانشگاه علوم پزشکی گرگان Journal of Gorgan University of Medical Sciences
Persian site map - English site map - Created in 0.04 seconds with 36 queries by YEKTAWEB 4660
Creative Commons License
This work is licensed under a Creative Commons — Attribution-NonCommercial 4.0 International (CC BY-NC 4.0)