Search published articles


Showing 3 results for Antimicrobial Resistance

P Torabi, M Azimirad, Z Hasani, M Janmaleki, H Peirovi, M Alebouyeh, Mr Zali,
Volume 8, Issue 1 (4-2014)
Abstract

Abstract Background and Objective: This study was aimed to determine the extent of bacterial contamination and drug resistance patterns of isolates colonized in colonoscope and endoscope and in relevant personnel. Material and Methods: A total of 107 samples were obtained from staff of endoscopy and colonoscopy units (SEU and SCU) and gastroenterological imaging equipment. For isolation and identification of the bacteria, swab culture method and biochemical identification test were used, respectively. Antimicrobial resistance profiles, multi-drug resistance (MDR) patterns and phenetic relatedness of these isolates were also analyzed according to standard methods. Results: Most frequent pathogenic bacteria among the SEU and gastroenterological imaging related equipments were included S. aureus (20.8 % and 0 %) Enterococcus spp. (0 % and 5.4%) Pseudomonas spp. (0% and 13.5 %), and Clostridium difficile (0% and 12.5%). Analysis of resistance phenotypes showed a high frequency of MDR phenotypes among the SEU (82.1%), and also in endoscopes, colonoscopes, and other equipments (20%, 50% and 100%, respectively). Phylotyping of S. epidermidis isolates showed the role of staff in transmission of resistance strains to medical equipments and also circulation of strains with identical resistance phenotype among the studied samples. Conclusion: High frequency of pathogenic bacteria in colonoscopes, endoscopes and in the staff of endoscopy & colonoscopy units, and also contamination of these instruments with MDR pathogens emphasize the need for proper disinfection of endoscopes and colonoscopes and also instruction of staff in these units. Key words: Bacterial Contamination Endoscope Colonoscope Antimicrobial Resistance Gastrointestinal Disease.
L Dolatshah, R Ghanbarpour, F Momeni, H Alizade,
Volume 8, Issue 1 (4-2014)
Abstract

Abstract Background and Objective: This study was aimed to determine the extent of bacterial contamination and drug resistance patterns of isolates colonized in colonoscope and endoscope and in relevant personnel. Material and Methods: A total of 107 samples were obtained from staff of endoscopy and colonoscopy units (SEU and SCU) and gastroenterological imaging equipment. For isolation and identification of the bacteria, swab culture method and biochemical identification test were used, respectively. Antimicrobial resistance profiles, multi-drug resistance (MDR) patterns and phenetic relatedness of these isolates were also analyzed according to standard methods. Results: Most frequent pathogenic bacteria among the SEU and gastroenterological imaging related equipments were included S. aureus (20.8 % and 0 %) Enterococcus spp. (0 % and 5.4%) Pseudomonas spp. (0% and 13.5 %), and Clostridium difficile (0% and 12.5%). Analysis of resistance phenotypes showed a high frequency of MDR phenotypes among the SEU (82.1%), and also in endoscopes, colonoscopes, and other equipments (20%, 50% and 100%, respectively). Phylotyping of S. epidermidis isolates showed the role of staff in transmission of resistance strains to medical equipments and also circulation of strains with identical resistance phenotype among the studied samples. Conclusion: High frequency of pathogenic bacteria in colonoscopes, endoscopes and in the staff of endoscopy & colonoscopy units, and also contamination of these instruments with MDR pathogens emphasize the need for proper disinfection of endoscopes and colonoscopes and also instruction of staff in these units. Key words: Bacterial Contamination Endoscope Colonoscope Antimicrobial Resistance Gastrointestinal Disease.
Mohammad Bokaeian, Shahram Shahraki Zahedani , Abbasali Delarampoor, Mohammadreza Atashgah, Bahram Dahmarde ,
Volume 12, Issue 3 (5-2018)
Abstract

ABSTRACT
Background and Objectives: The resistance of gram-negative bacteria to antibiotics has become a serious problem, which imposes a significant increase in treatment costs. Klebsiella pneumoniae is an important nosocomial pathogen from the Enterobacteriaceae family. The aim of this study was to investigate the frequency and pattern of antibiotic resistance in K. pneumoniae strains isolated from clinical samples.
Methods: This descriptive, cross-sectional study was performed on 150 K. pneumonia strains isolated from different clinical samples such as urine, sputum, blood, ulcers, lung secretions and abdominal abscess. Antibiogram test was performed using the disk diffusion method (Kirby-Bauer). Minimum inhibitory concentration of amikacin, tobramycin and gentamicin was determined via the E-test for 50 strains with high resistance rates.
Results: In this study, the highest rate of resistance was observed against carbenicilin, ceftriaxone, cefepime and streptomycin. K. pneumonia isolates were most frequent in urine and sputum samples. In the E-test, the highest rate of resistance was observed against gentamicin, tobramycin (16µg/ml) and amikacin (64µg/ml).
Conclusion: Based on our results, tigecycline, netilmicin, kanamycin and amikacin are the most effective antibiotics for the treatment of K. pneumoniae infections.
Keywords: Klebsiella pneumoniae, antimicrobial resistance, E-test method


Page 1 from 1     

© 2007 All Rights Reserved | Medical Laboratory Journal

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.