[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Indexing Sources::
Editorial Board::
Executive Members::
Articles Archive::
Instruction to Authors::
Peer-Review::
Contact Us::
Site Facilities::
::
Search in website

Advanced Search
Receive site information
Enter your Email in the following box to receive the site news and information.
:: Volume 17, Issue 3 (10-2015) ::
J Gorgan Univ Med Sci 2015, 17(3): 127-133 Back to browse issues page
Rapid detection of Mycoplasma pneumonia by Loop mediated isothermal amplification (LAMP)
Davudi-Asl F1 , Shahhosseiny MH * 2, Keshavarz F1
1- M.Sc Student in Cell and Molecular Biology, Science and Research Branch (Kordestan), Islamic Azad University, Sanandaj, Iran
2- Associate Professor, Department of Microbiology, Shahr-e-Qods Branch, Islamic Azad University, Tehran, Iran and Iranian Gene Fanavar Institute (IGF), Tehran, Iran , shahhosseiny@yahoo.com
Abstract:   (8432 Views)
Background and Objective: Mycoplasma pneumoniae bacteria, is one of the most important factor in causing of respiratory infections. Serological and molecular detection methods have their own limitation. Due to this limitation, the application of these methods in all diagnostic laboratories is not possible. Therefore this study was done to determine the rapid detection of Mycoplasma pneumonia by loop mediated isothermal amplification (LAMP). Methods: In this descriptive laboratory study, nasopharynx samples were collected from 92 patients with atypical pneumonia. DNA sample were extracted by boiling method. Six specific primer pairs were designed for LAMP technique by primer explorer ver 4 software. LAMP product identified by adding SYBR Green. Limit of detection and specificity tests have been done for optimizing LAMP test and optimized test carry out for each sample. Results: The LAMP test was optimized using the large Bst enzyme fragment at 66 degree temperature for 1 hour. The detection limit of the test obtained 1 CFU and the DNA replication does not observed in non of the examined pathogenic factors. Out of 92 clinical samples using LAMP technique, 73 cases were negative (80%) and 19 cases were positive (20%). Conclusion: The loop-mediated isothermal amplification technique is simple, convenient and available method for detection of Mycoplasma pneumoniae.
Keywords: Atypical pneumonia, Mycoplasma pneumoniae, Loop mediated isothermal amplification
Full-Text [PDF 248 kb] [English Abstract]   (19395 Downloads)    
Type of Study: Original Articles | Subject: Microbiology
Send email to the article author


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Davudi-Asl F, Shahhosseiny MH, Keshavarz F. Rapid detection of Mycoplasma pneumonia by Loop mediated isothermal amplification (LAMP). J Gorgan Univ Med Sci 2015; 17 (3) :127-133
URL: http://goums.ac.ir/journal/article-1-2514-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 17, Issue 3 (10-2015) Back to browse issues page
مجله دانشگاه علوم پزشکی گرگان Journal of Gorgan University of Medical Sciences
Persian site map - English site map - Created in 0.04 seconds with 36 queries by YEKTAWEB 4657