:: Volume 15, Issue 1 (3-2013) ::
J Gorgan Univ Med Sci 2013, 15(1): 103-109 Back to browse issues page
Assessment of partial distribution of the equivalent dose in radiology waiting room - Ardabil, Iran (2011)
Zand H * 1, Amani M2 , Mohammadi V3 , Valinezhad F3 , Hosseinzadeh S4
1- Radiologist , hamedzand30@gmail.com
2- Assistant Professor, Department of Radiology, Ardabil University of Medical Sciences, Ardabil, Iran
3- Radiologist
4- BSc of Radiology, Department of Radiology, Ardabil University of Medical Sciences, Ardabil, Iran
Abstract:   (14046 Views)
Background and Objective: The exposures related to the department of radiology can be considered as harmful agent for human. This study was done to assess the partial distribution of the equivalent dose in radiology waiting room in Ardabil, Iran. Materials and Methods: This descriptive analytical study was done in the radiology department and related waiting rooms of 4 teaching hospital and 3 private radiology sonography centers in Ardabil, Northwest of Iran, during 2011. The variables including type of radiography, the number and condition, staying duration in waiting room were considered for dosimetry. Data were analyzed using SPSS-18 and Chi-Square test. Results: The lowest radiation dose belong to one specialist radiology sonography center with 0.2±0.002 µS.h-1V, but for each radiography were determined to be 0.00275±0.004 µS.h-1V. The highest radiation dose belong to one specialist radiography sonography center with 0.4±0.045 µS.h-1V and for each radiography was 0.016±0.0006 µS.h-1V. Two teaching hospitals accompanied with three privates centers showed to have radiation dose-rate higher than 0.3 µS.h-1V (P<0.05). Conclusion: This study showed that the increasing radiation-dose rate (higher than 0.3 µS.h-1V) in teaching hospitals and private centers can be related to either the unit life or inadepuate of radiological protective shield.
Full-Text [PDF 276 kb] [English Abstract]   (20710 Downloads)    
Type of Study: Original Articles | Subject: Radiology
Send email to the article author


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Zand H, Amani M, Mohammadi V, Valinezhad F, Hosseinzadeh S. Assessment of partial distribution of the equivalent dose in radiology waiting room - Ardabil, Iran (2011). J Gorgan Univ Med Sci 2013; 15 (1) :103-109
URL: http://goums.ac.ir/journal/article-1-1694-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 15, Issue 1 (3-2013) Back to browse issues page
مجله دانشگاه علوم پزشکی گرگان Journal of Gorgan University of Medical Sciences
Persian site map - English site map - Created in 0.05 seconds with 36 queries by YEKTAWEB 4679
Creative Commons License
This work is licensed under a Creative Commons — Attribution-NonCommercial 4.0 International (CC BY-NC 4.0)